This list covers the basic details of the standard STS/Tyer
range of relays.
Data sheets are available on request.
Other types of relays can be supplied, and designed
where necessary to specific requirements. |
 |
| |
|
|
|
|
|
|
|
|
|
BR CAT. No. |
Pin Code |
B.R. SPEC |
DESCRIPTION |
Contact Config'n |
Coil Supply |
STS Part Ref. |
STS Label Ident |
TYPICAL APPLICATION |
|
85/0200 |
101 |
938A |
DC Track Relay 4 Ohm |
2F |
0.5V |
TY150 |
TY150-1-T |
4 ohm track relay 2F contacts |
|
85/0230 |
104 |
966F2 |
AC Immune Track Relay 70 Ohms |
2F |
4.0V |
TY153 |
TY153-3-TA |
70 ohm track relay for use in AC electrified areas |
|
85/0250 |
105 |
939A |
AC Immune Track Relay 20 Ohms |
2F |
2.0V |
TY153 |
TY153-1-TA |
20 ohm track relay for use in AC electrified areas |
|
85/0280 |
110 |
966F2 |
AC Immune Track Relay 9 Ohms |
2F |
1.4V |
TY153 |
TY153-2-TA |
9 ohm track relay for use in AC electrified areas |
|
85/0290 |
081 |
940A |
DC Lamp Proving Relays |
4F |
0.80A |
TY133 |
TY133-2-EC |
Proving of DC signal lamps |
|
85/0300 |
111 |
968A |
Aster Track Relay 250 Ohms |
2F |
0.17V |
TY152 |
TY152-1-T |
250 ohm track relay for electrified track circuits |
|
85/0350 |
001 |
930A |
Neutral Line Relay |
12F 4B |
24V |
TY82 |
TY82-1-N |
Line end interlocking |
|
85/0360 |
003 |
930A |
Neutral Line Relay |
8F 4B |
24V |
TY82 |
TY082-3-N |
Line end interlocking |
|
85/0370 |
002 |
930A |
Neutral Line Relay |
8F 8B |
24V |
TY82 |
TY082-5-N |
Line end interlocking |
|
85/0380 |
002 |
930A |
Neutral Line Relay |
6F 6B |
24V |
TY82 |
TY082-7-N |
Line end interlocking |
|
85/0390 |
002 |
930A |
Neutral Line Relay |
4F 4B |
24V |
TY82 |
TY082-9-N |
Line end interlocking |
|
85/0410 |
003 |
930A |
Neutral Line Relay |
12F 4B |
50V |
TY82 |
TY082-11-N |
Line end interlocking |
|
85/0420 |
003 |
930A |
Neutral Line Relay |
8F 4B |
50V |
TY82 |
TY082-13-N |
Line end interlocking |
|
85/0430 |
004 |
930A |
Neutral Line Relay |
8F 8B |
50V |
TY82 |
TY082-15-N |
Line end interlocking |
|
85/0440 |
004 |
930A |
Neutral Line Relay |
6F 6B |
50V |
TY82 |
TY082-17-N |
Line end interlocking |
|
85/0450 |
004 |
930A |
Neutral Line Relay |
4F 4B |
50V |
TY82 |
TY082-19-N |
Line end interlocking |
|
85/0500 |
002 |
930A |
Neutral Line Relay |
12F 4B |
24V |
TY82 |
TY082-2-ND |
Line end interlocking |
|
85/0510 |
004 |
930A |
Neutral Line Relay |
8F 4B |
24V |
TY82 |
TY082-4-ND |
Line end interlocking |
|
85/0520 |
002 |
930A |
Neutral Line Relay |
8F 8B |
24V |
TY82 |
TY082-6-ND |
Line end interlocking |
|
85/0530 |
002 |
930A |
Neutral Line Relay |
6F 6B |
24V |
TY82 |
TY082-8-ND |
Line end interlocking |
|
85/0540 |
002 |
930A |
Neutral Line Relay |
4F 4B |
24V |
TY82 |
TY082-10-ND |
Line end interlocking |
|
85/0560 |
003 |
930A |
Neutral Line Relay |
12F 4B |
50V |
TY82 |
TY082-12-ND |
Line end interlocking |
|
85/0570 |
003 |
930A |
Neutral Line Relay |
8F 4B |
50V |
TY82 |
TY082-14-ND |
Line end interlocking |
|
85/0580 |
004 |
930A |
Neutral Line Relay |
8F 8B |
50V |
TY82 |
TY082-16-ND |
Line end interlocking |
|
85/0590 |
004 |
930A |
Neutral Line Relay |
6F 6B |
50V |
TY82 |
TY082-18-ND |
Line end interlocking |
|
85/0600 |
004 |
930A |
Neutral Line Relay |
4F 4B |
50V |
TY82 |
TY082-20-ND |
Line end interlocking |
|
85/0620 |
1057 |
966F3 |
Neutral Relay Medium Duty Back Contacts |
8F 8MB |
24V |
TY178 |
TY178-1-NE |
An alternative to TY82 with larger current carrying
capacity on back contacts |
|
85/0630 |
1057 |
966F4 |
Neutral Relay Medium Duty Back Contacts |
8F 8MB |
24V ND |
TY178 |
TY178-2-NDE |
An alternative to TY82 with larger current carrying
capacity on back contacts |
|
85/0650 |
021 |
931A |
AC Immune Neutral Line Relay |
12F 4B |
24V |
TY83 |
TY083-1-NA |
Line end interlocking when AC voltage are present |
|
85/0660 |
021 |
931A |
AC Immune Neutral Line Relay |
8F 4B |
24V |
TY83 |
TY083-2-NA |
Line end interlocking when AC voltage are present |
|
85/0670 |
022 |
931A |
AC Immune Neutral Line Relay |
8F 8B |
24V |
TY83 |
TY083-3-NA |
Line end interlocking when AC voltage are present |
|
85/0680 |
022 |
931A |
AC Immune Neutral Line Relay |
6F 6B |
24V |
TY83 |
TY083-4-NA |
Line end interlocking when AC voltage are present |
|
85/0690 |
022 |
931A |
AC Immune Neutral Line Relay |
4F 4B |
24V |
TY83 |
TY083-5-NA |
Line end interlocking when AC voltage are present |
|
85/0710 |
023 |
931A |
AC Immune Neutral Line Relay |
12F 4B |
50V |
TY83 |
TY083-6-NA |
Line end interlocking when AC voltage are present |
|
85/0720 |
023 |
931A |
AC Immune Neutral Line Relay |
8F 4B |
50V |
TY83 |
TY083-7-NA |
Line end interlocking when AC voltage are present |
|
85/0730 |
024 |
931A |
AC Immune Neutral Line Relay |
8F 8B |
50V |
TY83 |
TY083-8-NA |
Line end interlocking when AC voltage are present |
|
85/0740 |
024 |
931A |
AC Immune Neutral Line Relay |
6F 6B |
50V |
TY83 |
TY083-9-NA |
Line end interlocking when AC voltage are present |
|
85/0750 |
024 |
931A |
AC Immune Neutral Line Relay |
4F 4B |
50V |
TY83 |
TY083-10-NA |
Line end interlocking when AC voltage are present |
|
85/0800 |
025 |
932A |
DC Biased AC Immune Relay |
12F 4B |
24V |
TY84 |
TY084-1-BA |
Line end interlocking when AC voltage are present
Polarity dependent |
|
85/0810 |
025 |
932A |
DC Biased AC Immune Relay |
8F 4B |
24V |
TY84 |
TY084-2-BA |
Line end interlocking when AC voltage are present
Polarity dependent |
|
85/0820 |
026 |
932A |
DC Biased AC Immune Relay |
8F 8B |
24V |
TY84 |
TY084-3-BA |
Line end interlocking when AC voltage are present
Polarity dependent |
|
85/0830 |
026 |
932A |
DC Biased AC Immune Relay |
6F 6B |
24V |
TY84 |
TY084-4-BA |
Line end interlocking when AC voltage are present
Polarity dependent |
|
85/0840 |
026 |
932A |
DC Biased AC Immune Relay |
4F 4B |
24V |
TY84 |
TY084-5-BA |
Line end interlocking when AC voltage are present
Polarity dependent |
|
85/0860 |
027 |
932A |
DC Biased AC Immune Relay |
12F 4B |
50V |
TY84 |
TY084-6-BA |
Line end interlocking when AC voltage are present
Polarity dependent |
|
85/0870 |
027 |
932A |
DC Biased AC Immune Relay |
8F 4B |
50V |
TY84 |
TY084-7-BA |
Line end interlocking when AC voltage are present
Polarity dependent |
|
85/0880 |
028 |
932A |
DC Biased AC Immune Relay |
8F 8B |
50V |
TY84 |
TY084-8-BA |
Line end interlocking when AC voltage are present
Polarity dependent |
|
85/0890 |
028 |
932A |
DC Biased AC Immune Relay |
6F 6B |
50V |
TY84 |
TY084-9-BA |
Line end interlocking when AC voltage are present
Polarity dependent |
|
85/0900 |
028 |
932A |
DC Biased AC Immune Relay |
4F 4B |
50V |
TY84 |
TY084-10-BA |
Line end interlocking when AC voltage are present
Polarity dependent |
|
85/0950 |
041 |
933A |
Slow to Operate AC Immune Relay |
8F 4B |
24V |
TY85 |
TY085-1-SPA |
Track circuit repeater |
|
85/0960 |
043 |
933A |
Slow to Operate AC Immune Relay |
8F 4B |
50V |
TY85 |
TY085-2-SPA |
Track circuit repeater |
|
85/1010 |
061 |
934A |
Slow to Release AC Immune Relay |
8F 4B |
24V |
TY86 |
TY086-1-SPA |
Signal control |
|
85/1015 |
008 |
935A |
Magnetically Latched Relay |
8F 6B |
50V |
TY87 |
TY087-4-L |
Interlocking |
|
85/1020 |
063 |
934A |
Slow to Release AC Immune Relay |
8F 4B |
50V |
TY86 |
TY086-2-SPA |
Signal control |
|
85/1070 |
009 |
935A |
Magnetically Latched Relay |
11F 4B |
24V |
TY87 |
TY087-1-L |
Interlocking |
|
85/1080 |
011 |
935A |
Magnetically Latched Relay |
11F 4B |
50V |
TY87 |
TY087-2-L |
Interlocking |
|
85/1130 |
014 |
936A |
Magnetic Stick Relay |
12F 4B |
24V |
TY151 |
TY151-1-PS |
|
|
85/1140 |
014 |
936A |
Magnetic Stick Relay |
8F8B |
24V |
TY151 |
TY151-2-PS |
|
|
85/1160 |
016 |
936A |
Magnetic Stick Relay |
12F 4B |
50V |
TY151 |
TY151-3-PS |
|
|
85/1170 |
016 |
936A |
Magnetic Stick Relay |
8F8B |
50V |
TY151 |
TY151-4-PS |
|
|
85/1300 |
081 |
940A |
DC Lamp Proving Relays |
4F |
0.80A |
TY133 |
TY133-1-EC |
Proving of DC signal lamps |
|
85/1350 |
071 |
941A |
AC Lamp Proving Relays |
4F |
0.18A |
TY132 |
TY132-2-ECX |
Proving of AC signal lamps |
|
85/1400 |
070 |
942A |
AC Lamp Proving Relays |
2F 2B |
0.78A |
TY132 |
TY132-1-UCX |
Series proving of lamps in junction indicator (5 lamps
110V 25W) |
|
85/1450 |
091 |
945A |
DC Lamp Proving Relays |
4F 2B |
1.00A |
TY133 |
TY133-1-ECF |
Proving of level crossing flashing signals |
|
85/1505 |
170 |
943 |
DC Biased AC Immune Contactor Relay |
2HF 4B |
24V |
TY154 |
TY154-2-BCA |
For Point Machine operation |
|
85/1515 |
172 |
943 |
DC Biased AC Immune Contactor Relay |
2HF 4B |
50V |
TY154 |
TY154-3-BCA |
For Point Machine operati |